Specifications
- Total Leakage Current Range : 1 μA to 20 mA
- Resistive Leakage Current Range : 1 μA to 20 mA
- Resolution : 1 μA
- Accuracy : Value ± 5% ± 1 μA
- Inputs : Wireless Clamp on CT and Wireless Field Probe optional external field PT Input (Voltage Peak method as per IEC 60099-5-A1 for GIS)
- Display : 4 line x 20 character large backlit LCD with large font
- Compensation : Automatic for System Harmonics, Temperature & System Voltage
- Temperature Sensor : Inbuilt Platinum Resistance Thermometer with measurement range of -20°C to 55°C
- Self-calibration Check : Available
- PC Connectivity : USB Port (Standard), RS 232 & Ethernet (Optional)
- Memory : Storage capacity of 2000 results
- Printer : 58mm Inbuilt Thermal Printer
- Power : Battery as well as Mains powered Main Unit / Battery powered CT and FP Units
- Internal Battery : SA30i+ – 11.1 V / 2200mAh Internal Rechargeable battery, CT Unit – 11.1 V / 1150mAh Rechargeable battery, Field Probe Unit – 11.1 V / 1150mAh Rechargeable battery.
- Mains Supply : 88 to 264 VAC, 47 to 63 Hz, Single Phase
- Battery Charger : Inbuilt in Main Unit, Connection to CT and Field Probe Provided