BLUe Series

Battery Loading Unit

Battery banks have become an inseparable part of uninterrupted or back-up power supply arrangements in various industries like Power, Telecom, IT etc. In substations the critical protection, control & communication systems run on battery power. Hence the reliability of these battery banks is crucial to ensure smooth operation of equipment which they are serving. The capacity of battery may get reduced significantly before the expected life span of battery due to various reasons. The only way to assess the continual health of battery banks is periodical maintenance inspection & testing. Conducting a discharge test on batteries is most effective way to check the battery capacity.SCOPE introduces BLUe Series Battery Loading Units; these are moveble instruments for controlled & monitored discharge of batteries. They are designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Each single autonomous unit having built-in display, keypad and wireless communication with computer makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents.Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit – CellMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to computer via wireless communication. Each BLUe unit is supplied with computer downloading & analysis software for real time monitoring of discharge process.

Measurement

Easy user interface with direct display of voltage & discharge current makes discharging a very easy task. Different models cover different types of cells (1.2V, 2V, 6V and 12V) and battery banks (24V, 48V, 110V, 220V and 380V). Discharge time, Discharge capacity, cell cut-off voltage & total cut-off voltage these are the four options available in BLUe to stop/auto shutdown the discharging process.

The optional CellMon – Data Acquisition Unit monitors discharging values of each cell & could be viewed on the LCD display of the instrument or computer simultaneously by using the analyzing software. Wireless communication technology enables it to continuously monitor & display the real time discharge process of all individual cells via monitoring terminal. Thus surveillance of each cell is done as well as suspected cell can be targeted & removed.

Optional Cell Monitoring Unit – CellMon

CellMon contiously monitors voltage of each cell connected to it and wirelessly sends data to BLUe main unit. It is rugged and capable to monitor all type of batteries (1.2V, 2V, 6V and 12V). Single CELLMon can be connected with 12 cells of 1.2V, 2V or 4 cells of 6V / 12V. BLUe can record overall voltage discharge current & discharge capacity even without CELLMon

TECHNICAL DATA

Full Product Specifications

 

BLUe0512/05130522/0523084208521111/11121120A

/1120 B

1121/11221131
ApplicationTTTWPT/PT/PT/P
 

Discharge Voltage : Current

 

48V: 200 /

300A

24V: 200 /

300A

48V: 200 /

300A

24V: 100A

36V: 150A

48V: 200A

80V: 200A

12V: 100A

24V: 200A

36V: 200A

48V: 200A

80V: 200A

 

110V: 100

/ 200A

12V: 50 /

50A

110V: 50 /

25A

48V: 100 /

200A

110V: 100

/

200A

 

12V: 100A

24V: 50A

110V: 75A

AccuracyCurrent : Value ± 1%; Voltage : 0.5%
ResolutionCurrent : 0.1 A or 0.5% of range whichever is higher; Voltage : 0.1V
PMax (kW)11 / 16.511 / 16.518.418.412.6 / 256.5 / 3.2512.6 /

25

9.5

Application : P – Power Utility, T – Telecom, U – UPS, W – Wide Voltage Range

Related Products

Professional meter for photovoltaic installations up to 1500 VThe PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. It can be used for category 1 measurements according to EN 62446-1. It allows the measurement of the I-U curve for category 2 according to EN 62446-1. Furthermore, it also converts measured parameters into STC conditions according to EN IEC 60891. Comprehensive, yet simple to use, it flawlessly performs its tasks in monitoring the safety and efficiency parameters of photovoltaic (PV) installations.
HISAC Ultima – new generation Circuit Breaker Dynamic Test Set from SCOPE …. The ultimate solution for testing Circuit Breakers of all types. HISAC Ultima is the most complete analyser for checking the dynamic performance of CBs in live EHV switchyards upto 765 kV.HISAC Ultima can carry out Dynamic Contact Resistance Measurement on SIX breaks of THREE poles in one operation thereby significantly reducing stress on CB & testing downtime.HISAC Ultima with DCRM+ ensures end users safety by providing Dual Earth Test, in which Circuit Breaker will be grounded from both sides while conducting the test.It offers flexibility to create pre-programmed Test Plans including all test settings for all types of circuit breakers available in a switchyard that can simply be recalled at the time of actual testing. This saves you from doing all settings in switchyards.The Analysis software offers a range of utilities which enables effective Condition Monitoring of CB by comparing present test data with previous signatures and predicting future performance.
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing. It is also used to test the Turns Ratio of Current Transformers and for other applications that require variable high currents. The Kit is designed for most optimal use of man and machine and is suitable to work in live switchyard conditions. Prima consists of a Control Unit and a low weight Loading Transformer, enabling the user to take the Loading Transformer nearest to the CT terminal. Thus, the weight of both the output lead and overall kit reduces considerably. The innovative design of Prima gives the ultimate flexibility to the user to use the full capacity of the Loading Transformer by adjusting the output voltage and current as per requirement.
HPT Series Hi-Pot Test Sets is available in three different combinations, viz., Power Frequency AC, DC and AC-DC Combined HV Test Sets for testing of transformers, motors, insulators, cables etc. Further, these test sets are capable of giving continuously variable HV from zero to maximum rated output voltage.HPT Series testers are specifically designed for safe and accurate measurement of leakage current to evaluate insulation integrity. These testers are moveble, one end ground test systems, ideal for HV testing. Accurate leakage measurements are ensured by placing the current meter in the return path of the HV. Years of Design, engineering and manufacturing experience have made our HPT testers the most durable, easily operated and the best designed sets in the segment. The product has been designed considering the importance of safety of the operator. The kit has various interlock to avoid any kind of accident while doing the high voltage testing.