LED Smart Street Light

Smart Street Light Solution

 

  • High Performance Price Ratio
    • Higher efficacy LED by Lumileds.
    • Updated driver brand SOSEN,MOSO and INVENTRONICS.
    • Convenient for installation and maintenance.
    • Glass cover.
  • Multiple Configurations Optional
    • Available 10KV SPD
    • Optional Photocell, timer dimming, DALI, 0-10V dimming
    • Optional Intelligent control system with NEMA interface is optional.
  • Wider Application
    • SHINE SH31 series LED street light will provide the better
      lumen output, better stability and very long lifetime.
    • Up to 5 years warranty for whole fixture.
    • It can be applied to streets, roads, highways, squares, parks and
      parking lots.

Produ

TECHNICAL DATA

Full Product Specifications

Related Products

Next generation three phase fully programmable smart energy meter with robust performance of high accuracy, high reliability, wide measurement range, and low power consumption, etc. The meter is fully compliant with IEC 62052-11:2020, IEC62053-21:2020, IEC62053-23:2020 and IEC62052-31:2016, OIML and DLMS/COSEM standards, allowing billing and management applications in IEC compliant countries for residential, commercial and industrial energy measurement and management.A Transformer Operated measurement (CT Connected) meter, covering wide voltage range of AC active/reactive energy with frequency of 50/60Hz. It can provide bi-directional communication with advanced information to utility data management system and end-customer, It can be read locally using HHU via optical port, as well as remotely via modular communication channel of PLC/RF/GPRS/GSM/LTE/NB-IOT installed in meter body under a sealable cover and connected to meter mainboard thru serial port, which make it possible for remote data access by DCU or MDCS. It also supports to control an External circuit breaker (ECB) via Output relay or RS-485 (Using RJ-45 connector) over MODBUS. The meter is designed with a built-in GPS modem which can triangulate signal from GPS satellite to position the location of the meters installed and push to the HES.
Overhead type Line Fault Indicators is based on the sensor that through Current Transformer (CT) to get the line current signal through smart processor and calculation to judge the short circuit or ground fault. The sensor ablet to warn the user through red LED equipped. It is beneficial for power management to find the fault points and to help in restoring the faulty line faster.
DLIM-412 Industrial 4.0 Technology Application Training System is one engineer teaching system following the latest industrial 4.0 technology, it may be used for TVET vocational school to realize training projects like MOUDLEBUS communication between PLC and RFID; Profinet communication between PLC and PLC; Communication between MES and PLC; Application of bus communication technology; Application of motor drive technology; Mechatronics collaborative simulation: mechanical interference, mechanism kinematics etc.
Fluke 83V and 87V Digital Multimeters is For all detailed specifications.Accuracy is given as ±([% of reading] + [number of least significant digits]) at 18 °C to 28 °C, with relative humidity up to 90 %, for a period of one year after calibration. For Model 87 in the 41⁄2-digit mode, multiply the number of least significant digits (counts) by 10. AC conversions are ac-coupled and valid from 3 % to 100 % of range. Model 87 is true-rms responding. AC crest factor can be up to 3 at full scale, 6 at half scale. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a crest factor up to 3.