AR700

Defect Location in High-Voltage Equipment Insulation by Acoustic PD

The AR700 measures acoustic signals with multiple relocatable acoustic sensors mounted on the transformer. The software determines the defect location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer.AR700 device is used for measuring of acoustic signals on the external surfacesof gas-insulated switchgears, power transformers and other grounded tank high-voltage equipment.The acoustic signals are caused by partial discharges in the insulation, which is the site of the defects.The advantage of AR700 device is the quick installation of the relocatable acoustic PD sensors on the grounded external surface of high-voltage equipment. The sensors have magnetic holders thus making it unnessary to de-energize the equipment for the sensors installation.AR700 device has 4 synchronic channels for acoustic signal measurement. This gives the possibility not only to detect defects in the insulation, but also to locate them. The 3D location function of the AR700 device is unique for acoustic devices.
  • The signal analyses and the PD zone location can be carried out both in manual and automatic
  • Software calculates the fault location based on the time difference between the incoming signals and report is generated regarding PD source
  • Convenient and handy – light weight, small size and battery operated
  • Can be used for multiple assets like Transformers, CTs, GIS, Cables, Switchgear Panel
  • Defect type identification by synchronised measurement of PD

TECHNICAL DATA

Full Product Specifications

ParametersAR700
Acoustic channels for PD measuring4
Frequency range of acoustic sensors30 – 300 kHz
High-frequency channels for PD measuring1
Frequency range of high-frequency sensors0.1 – 20 MHz
LCD resolution480x272pixel
computer connectionUSB
Operating temperature range-20 to +60ºC
Humidity<98%, non-condensing.
Operating time from build-in accumulator8 hours
Device weight, without sensors1.1 kg
Dimensions of transportation case520x435x230mm
Device weight in carrying case12kg

Related Products

Sonel MIC-5050 insulation resistance meter constitute a reliable tool to measure insulation resistance up to 20 TΩ. The instrument is designed for control tests of electric shock protection in AC power networks. It is used to carry out measurements whose results determine the safety condition of the installation.The meter is recommended for electric power services that inspect the condition of electroinsulating materials.
HISAC Ultima – new generation Circuit Breaker Dynamic Test Set from SCOPE …. The ultimate solution for testing Circuit Breakers of all types. HISAC Ultima is the most complete analyser for checking the dynamic performance of CBs in live EHV switchyards upto 765 kV.HISAC Ultima can carry out Dynamic Contact Resistance Measurement on SIX breaks of THREE poles in one operation thereby significantly reducing stress on CB & testing downtime.HISAC Ultima with DCRM+ ensures end users safety by providing Dual Earth Test, in which Circuit Breaker will be grounded from both sides while conducting the test.It offers flexibility to create pre-programmed Test Plans including all test settings for all types of circuit breakers available in a switchyard that can simply be recalled at the time of actual testing. This saves you from doing all settings in switchyards.The Analysis software offers a range of utilities which enables effective Condition Monitoring of CB by comparing present test data with previous signatures and predicting future performance.
SIM Filter is a passive filter which uses energy of surge generator for stabilizing the SIM Filter, CFL SIMF works in conjunction with SCOPE’s Cable Fault Pre Locator CFL Cable Fault Surge Generator, CFL SG Series, up to 16kV
Audio Frequency Generator has been designed to be used for cable route tracing, pin-pointing of low resistance welded faults, joint location and cable identification.