Earth Fault Indicator (EFI)

Cable Faulty detector for MV and LV Distribution Network application

SNV-EFI earth fault indicator, it Widely used in various ring cabinets, high/ Medium or low -voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type ofpower grid in the Low/medium voltage network. The use of cable type grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and theefficiency of fault handling. The design uses electromagnetic induction, and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability

TECHNICAL DATA

Full Product Specifications

  • Brand : SNOVA
  • Model : SNV-EFI
  • Voltage Grade : AC110V-40.5KV
  • Frequency : 50HZ/60HZ
  • Earth Fault Alarm Current (Optional) : 10/25/50/75/100/12, 5A/250, Default :50A
  • Alarm current accuracy : ±10%
  • Rated frequency withstand voltage : 2KV/1min
  • Relay contact capacity : ≤95W
  • ER14505 battery : Lithium battery (LiSOCl2) 3.6V/2700mAh
  • Battery life : ≥10 year
  • Low voltage alarm of battery : ≤2.5V
  • Earth fault sensor copper cable length : 5 meter,or customized
  • Temperature : -40℃~+60℃
  • Humidity : ≤95%RH
  • Display unit : IP 65
  • Sensor CT : IP 67

Related Products

Next generation three phase fully programmable smart energy meter with robust performance of high accuracy, high reliability, wide measurement range, and low power consumption, etc. The meter is fully compliant with IEC 62052-11:2020, IEC62053-21:2020, IEC62053-23:2020 and IEC62052-31:2016, OIML and DLMS/COSEM standards, allowing billing and management applications in IEC compliant countries for residential, commercial and industrial energy measurement and management.A Transformer Operated measurement (CT Connected) meter, covering wide voltage range of AC active/reactive energy with frequency of 50/60Hz. It can provide bi-directional communication with advanced information to utility data management system and end-customer, It can be read locally using HHU via optical port, as well as remotely via modular communication channel of PLC/RF/GPRS/GSM/LTE/NB-IOT installed in meter body under a sealable cover and connected to meter mainboard thru serial port, which make it possible for remote data access by DCU or MDCS. It also supports to control an External circuit breaker (ECB) via Output relay or RS-485 (Using RJ-45 connector) over MODBUS. The meter is designed with a built-in GPS modem which can triangulate signal from GPS satellite to position the location of the meters installed and push to the HES.
Overhead type Line Fault Indicators is based on the sensor that through Current Transformer (CT) to get the line current signal through smart processor and calculation to judge the short circuit or ground fault. The sensor ablet to warn the user through red LED equipped. It is beneficial for power management to find the fault points and to help in restoring the faulty line faster.
Fluke 83V and 87V Digital Multimeters is For all detailed specifications.Accuracy is given as ±([% of reading] + [number of least significant digits]) at 18 °C to 28 °C, with relative humidity up to 90 %, for a period of one year after calibration. For Model 87 in the 41⁄2-digit mode, multiply the number of least significant digits (counts) by 10. AC conversions are ac-coupled and valid from 3 % to 100 % of range. Model 87 is true-rms responding. AC crest factor can be up to 3 at full scale, 6 at half scale. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a crest factor up to 3.
The meter is a Class 1.0 Accuracy electric energy metering instrument with the high manufacturing technology to realize the measurement and control of active energy, and it supports the standard DLMS/COSEM specification, to realize the interoperability under master station.The meter mainly includes measurement unit, display unit, button unit, real-time clock unit, function of infrared and Bluetooth communication with other auxiliary ports that can be programmable.