  • Modular Expansion
  • Remote Monitoring
  • Lithium Iron Phosphate Technology
  • Long Service Life
HPT Series Hi-Pot Test Sets is available in three different combinations, viz., Power Frequency AC, DC and AC-DC Combined HV Test Sets for testing of transformers, motors, insulators, cables etc. Further, these test sets are capable of giving continuously variable HV from zero to maximum rated output voltage.HPT Series testers are specifically designed for safe and accurate measurement of leakage current to evaluate insulation integrity. These testers are moveble, one end ground test systems, ideal for HV testing. Accurate leakage measurements are ensured by placing the current meter in the return path of the HV. Years of Design, engineering and manufacturing experience have made our HPT testers the most durable, easily operated and the best designed sets in the segment. The product has been designed considering the importance of safety of the operator. The kit has various interlock to avoid any kind of accident while doing the high voltage testing.
IPC is used for simultaneous penetration of insulation on LV ABC conductors and for connecting of conductors for street lighting. Connector is manufactured in such way that it enables connection of LV ABC and branch conductor regardless of whether it is an aluminum or copper conductor. The body of the connector is made of Heat and UV resistant plastic and the elastomer insert eliminates the appearance of electrolytic corrosion since it prevents the appearance of moisture at contact points. The contacts are protected with electric contact grease. Mounting under voltage is possible but with mandatory use of adequate protection equipment. Ring-spanner or tubular spanner.
DLIM-412 Industrial 4.0 Technology Application Training System is one engineer teaching system following the latest industrial 4.0 technology, it may be used for TVET vocational school to realize training projects like MOUDLEBUS communication between PLC and RFID; Profinet communication between PLC and PLC; Communication between MES and PLC; Application of bus communication technology; Application of motor drive technology; Mechatronics collaborative simulation: mechanical interference, mechanism kinematics etc.
Overhead type Line Fault Indicators is based on the sensor that through Current Transformer (CT) to get the line current signal through smart processor and calculation to judge the short circuit or ground fault. The sensor ablet to warn the user through red LED equipped. It is beneficial for power management to find the fault points and to help in restoring the faulty line faster.
Low voltage metal oxide surge arresters with a silicone housing NNO and MOSPO are designed for installation in low voltage power lines or junction boxes with voltages up to 1 kV.They serve as the initial level of protection against surges and other transients. The varistors of low voltage surge arresters NNO and MOSIPO are directly molded by silicone rubber, providing them with a high level of ingress protection rated at IP 67.
Suspension clamp PS 1500 is designed to suspend LV ABC with insulated neutral messenger of cross-section between 16 mm² and 71,5 mm². It is resistant to environmental and mechanical effects and UV radiation since it is made of material of high tensile strength and stable structure. Suspension clamp allowsturning angle of 30/60°. It is installed using no tools and does not contain parts which can fall off during installation.
Next generation three phase fully programmable smart energy meter with robust performance of high accuracy, high reliability, wide measurement range, and low power consumption, etc. The meter is fully compliant with IEC 62052-11:2020, IEC62053-21:2020, IEC62053-23:2020 and IEC62052-31:2016, OIML and DLMS/COSEM standards, allowing billing and management applications in IEC compliant countries for residential, commercial and industrial energy measurement and management.A Transformer Operated measurement (CT Connected) meter, covering wide voltage range of AC active/reactive energy with frequency of 50/60Hz. It can provide bi-directional communication with advanced information to utility data management system and end-customer, It can be read locally using HHU via optical port, as well as remotely via modular communication channel of PLC/RF/GPRS/GSM/LTE/NB-IOT installed in meter body under a sealable cover and connected to meter mainboard thru serial port, which make it possible for remote data access by DCU or MDCS. It also supports to control an External circuit breaker (ECB) via Output relay or RS-485 (Using RJ-45 connector) over MODBUS. The meter is designed with a built-in GPS modem which can triangulate signal from GPS satellite to position the location of the meters installed and push to the HES.
MagD is specially designed to cater the needs of testing of Instrument Transformers. Before new systems are put into service or after any occurrence of fault, Instrument Transformers need to be tested for their outputs. It is to be ensured that Instrument Transformers give proper outputs to protection relays.